Search results for "Electrical treeing"
showing 6 items of 6 documents
Electrical Aging Tests on Enameled Wire Exposed to Gamma Irradiation
2011
Partial Discharge on-line measures in cable's EPR insulation
2004
In this paper, an experimental study, carried out on an operating MV cable, is presented. The aim is to identify, locate and characterize defects in the cable's EPR (ethylene-propylene copolymer rubber) insulation. Direct partial discharge measurements have been compared to those obtained by high frequency electromagnetic field measures. The latter have been carried out using a sensor which does not require any galvanic connection with the system under test and that performs an intrinsic localization of the defect. Moreover, an analysis of an MV cable junction has been carried out using the same tools.
A novel flexible approach for prediction and on line diagnostic of partial discharge
2004
Partial discharges (PD), due to unavoidable local defects produced by the industrial manufacturing process, can determine local erosion of the material that may cause the electrical breakdown of the component in which the dielectric material represents the fundamental part. Recently, improved diagnostics of electrical insulation systems by means of electric PD measurements through a stochastic processing of the acquired data have been carried out. In this way, the identification of the defects as well, as the separation of multiple defects simultaneously active, have been performed. In this paper, a novel flexible approach for the on-line characterization of the defects in a dielectric mate…
Model of ageing inception and growth from microvoids in polyethylene-based materials under AC voltage
2008
Several degradation mechanisms may affect polymeric insulation system reliability. Some authors postulate that, even in a perfect dielectric, nanoscale cavities can enlarge due to various mechanisms (from mechanical fatigue to lowering of the degradation reaction energy barrier) up to a point where highly energetic phenomena, which bring about breakdown, can be incepted. Other authors are more focused on the inherent limits of manufacturing processes, which leave cavities within the insulation system whose size is large enough to cause electron avalanches, thus a measurable partial discharge (PD) activity, from the time the system is put in service or as a function of external factors (e.g.…
Electrical treeing in EVA-bohemite and EVA-montmorillonite nanocomposites
2009
The present experimental work focuses on the growth of electrical treeing inside different Ethylene-vinyl acetate (EVA) nanocomposites containing Bohemite (an aluminum oxide hydroxide) and Montmorillonite (a phyllosilicate clay mineral) nanoparticles. Bohemite and Montmorillonite particles have different aspect ratios: the first one has a nanometric cube-like symmetry, while the latter has a typical layered structure. The results evidence that the growth of the electrical treeing inside the original polymer can be altered significantly by the dispersion of inorganic nanoparticles.
Electrical tree growth in EVA-layered silicate nanocomposites
2006
This work deals with the growth of electrical treeing in different EVA-layered silicate nanostructured compounds. The experimental activity evidenced that the intercalated nanocomposites have longer lifetimes than pure EVA under the same constant AC stress conditions. A monitoring of the tree growth morphology allowed to evidence very interesting features of the intercalated nano-compounds showing a barrier effect to the treeing path. A preliminary investigation on the possible arrangement of the filler particles inside the matrix was also carried out.